Representative inventory. These devices are a realistic K-12 mix used to exercise the platform — not MSAD 17's actual equipment list. Add connectors via Integrations (prepackaged + auto-discovery). CSV import still works. No new hardware is required.
Manufacturers
3
Axis 12 · Hanwha Vision 4 · Hikvision 3
NDAA §889 covered
3 cams
+ 1 recorder · not eligible for federal-grant (COPS) spend
Firmware below policy
5
OHCHS-C-006, OHCHS-C-007, OHCHS-C-008, OHCHS-C-010, PES-C-004
Wiegand readers
2
OHCHS-D-05, PES-D-05
Doors w/o camera map
0
Alarms on these points cannot auto-pop video
| ID | Site | Door | Controller · IP | Interface | Reader · protocol | Lock | Cameras | Held | Status |
|---|---|---|---|---|---|---|---|---|---|
| OHCHS-D-01 | OHCHS | Main Vestibule Outer entry · Locked · visitor buzz-in |
Mercury LP1502 · OHCHS-ACS-01 10.17.21.10 |
LP1502 onboard rdr 1 | HID Signo 40 OSDP v2 · Secure Channel |
Electrified mortise (fail-secure) | OHCHS-C-001 OHCHS-C-002 |
30s | SECURE |
| OHCHS-D-02 | OHCHS | Main Vestibule Inner entry · Locked · office release |
Mercury LP1502 · OHCHS-ACS-01 10.17.21.10 |
LP1502 onboard rdr 2 | Office remote release OSDP v2 · Secure Channel |
Electric strike (fail-secure) | OHCHS-C-002 OHCHS-C-003 |
20s | SECURE |
| OHCHS-D-03 | OHCHS | Staff Entry West entry · Locked · credential |
Mercury LP1502 · OHCHS-ACS-01 10.17.21.10 |
MR52-S3 #1 port 1 | HID Signo 20 OSDP v2 · Secure Channel |
Electrified mortise (fail-secure) | OHCHS-C-004 | 30s | SECURE |
| OHCHS-D-04 | OHCHS | Gym Exterior Pair exterior · Monitored · egress only |
Mercury LP1502 · OHCHS-ACS-01 10.17.21.10 |
MR52-S3 #1 port 2 | None (DPS + REX only) Monitored input |
Exit device, no exterior trim | OHCHS-C-008 OHCHS-C-007 |
60s | SECURE |
| OHCHS-D-05 | OHCHS | Tech Wing Exterior exterior · Locked · credential |
Mercury LP1502 · OHCHS-ACS-02 10.17.21.11 |
MR52-S3 #2 port 1 | HID iCLASS SE R40 Wiegand 26-bit (unencrypted) |
Electric strike (fail-secure) | OHCHS-C-011 OHCHS-C-010 |
30s | FORCED |
| OHCHS-D-06 | OHCHS | Loading Dock exterior · Locked · credential |
Mercury LP1502 · OHCHS-ACS-02 10.17.21.11 |
MR52-S3 #2 port 2 | HID Signo 20 OSDP v2 · Secure Channel |
Electrified mortise (fail-secure) | OHCHS-C-012 | 120s | SECURE |
| PES-D-01 | PES | Main Entry Outer entry · Locked · visitor buzz-in |
HID VertX V1000 · PES-ACS-01 10.17.41.10 |
V100 #1 rdr 1 | HID Signo 40 OSDP v2 · Secure Channel |
Electrified mortise (fail-secure) | PES-C-001 PES-C-002 |
30s | SECURE |
| PES-D-02 | PES | Vestibule Inner entry · Locked · office release |
HID VertX V1000 · PES-ACS-01 10.17.41.10 |
V100 #1 rdr 2 | Office remote release OSDP v2 · Secure Channel |
Electric strike (fail-secure) | PES-C-002 | 20s | SECURE |
| PES-D-03 | PES | Staff Entry East entry · Locked · credential |
HID VertX V1000 · PES-ACS-01 10.17.41.10 |
V100 #2 rdr 1 | HID Signo 20 OSDP v2 · Secure Channel |
Electrified mortise (fail-secure) | PES-C-006 | 30s | SECURE |
| PES-D-04 | PES | Playground Gate exterior · Monitored · recess schedule |
HID VertX V1000 · PES-ACS-01 10.17.41.10 |
V200 #1 input 3 | None (gate contact) Monitored input |
Gate latch, contact only | PES-C-004 | 120s | HELD OPEN |
| PES-D-05 | PES | Kitchen Service exterior · Locked · credential |
HID VertX V1000 · PES-ACS-01 10.17.41.10 |
V100 #2 rdr 2 | HID iCLASS SE R10 Wiegand 26-bit (unencrypted) |
Electric strike (fail-secure) | PES-C-005 | 60s | SECURE |
| OHMS-D-01 | OHMS | Secure Vestibule Outer (design) entry · Design |
Owner requirement OR-ACS-01 — |
— | OSDP v2 SC reader required OSDP v2 · Secure Channel (spec) |
Electrified mortise (spec) | OHMS-C-001 | 30s | PLANNED |